Melting Point Apparatus LDMP-B13

Melting Point Apparatus LDMP-B13 offers desktop design, Automatic detection method, with cooling function. Equipped with Peltier precise temperature function, In line with international standards such as CE & ISO for determination of the melting point of oils and fats. With addition of either high-definition camera or high definition video and camera technology, to delivers accurate, stable results, and user can clearly see the whole process of sample melting, automatic detection to eliminate the subjective error to determine the melting point.

  • Temperature control range 4 to 100℃
    Detection method Fully automatic (compatible with Semi-automatic)
    Capacity per batch 2 pcs/batch
    Temperature resolution 0.1℃
    Temperature gradients (0.1 to 10.0)℃/Min
    Temperature accuracy ±0.3℃
    Repeatability 0.1℃/Min , ±0.1℃
    Camera & Video Camera & Video
    Video playback Yes
    Operator account 20
    Result storage 1000
    SD card capacity 16 G
    Display TFT Touch screen
    Interface USB RS232 SD card Enternet
    Opening capillary size I.D>1.0 mm, O.D.1.4 mm
    Power 110 to 220V 50, 60Hz 120W
    Dimension 400 × 280× 330 mm
    Weight 5 kg
    • TFT touch screen display
    • Automatic detection method, with cooling function
    • Capacity per batch is 2 pcs
    • Designed with a key automatic detection function
    • Use of double opening capillary size I.D>1.0 mm,O.D.1.4 mm
    • In line with international standards such as CE & ISO
    • Adopted with Peltier precise temperature function technology
  • It finds application across finding meting point of oil and fat in food and drug industry, biochemistry, medicines, mining, water management industry.

Melting Point Apparatus LDMP-A13

  • RT to 400°CTemperature Range
  • Built-in Cooling FanCooling Function
  • Capillary tubeSample Cell
  • External diameter: 1.6 mm internal diameter: 1.2 mmSample Tube

Melting Point Apparatus LDMP-A12

  • RT to 320°CTemperature Range
  • NOCooling Function
  • Capillary tubeSample Cell
  • External diameter: 1.6 mm internal diameter: 1.2 mmSample Tube

Melting Point Apparatus LDMP-B12

  • RT to 100℃Temperature control range
  • Fully automatic (compatible with Semi-automatic)Detection method
  • 2 pcs/batchCapacity per batch
  • 0.1℃Temperature resolution
Melting Point Apparatus LDMP-A20
  • Room temperature to 350 ℃Temperature range
  • Fully automatic (compatible with manual)Detection mode
  • 4 / batchProcessing capacity
  • Automatically judge color samplesJudgment ability
Melting Point Apparatus LDMP-B10
  • RT to 100℃Temperature control range
  • Semi-automaticDetection method
  • 2 pcs/batchCapacity per batch
  • 0.1℃Temperature resolution

Melting Point Apparatus LDMP-B11

  • 6 to 100℃Temperature control range
  • Semi-automaticDetection method
  • 2 pcs/batchCapacity per batch
  • 0.1℃Temperature resolution

Melting Point Apparatus LDMP-B20

  • Room temperature to 280˚CMeasurement range
  • Silicon oilHeating conducting medium
  • 0.1˚CMinimum digital display
  • 0.5, 1.0, 1.5, 3.0 ˚C/minLinear heating up rate

Melting Point Apparatus LDMP-A12

  • RT to 320°CTemperature Range
  • NOCooling Function
  • Capillary tubeSample Cell
  • External diameter: 1.6 mm internal diameter: 1.2 mmSample Tube
Melting Point Apparatus LDMP-A20
  • Room temperature to 350 ℃Temperature range
  • Fully automatic (compatible with manual)Detection mode
  • 4 / batchProcessing capacity
  • Automatically judge color samplesJudgment ability
Melting Point Apparatus LDMP-A13
  • RT to 400°CTemperature Range
  • Built-in Cooling FanCooling Function
  • Capillary tubeSample Cell
  • External diameter: 1.6 mm internal diameter: 1.2 mmSample Tube