Dry bath incubator LDBI-A20

Dry bath incubator LDBI-A20 is a compact, energy-efficient equipment which is applicable to 24 V power adapter. It fits perfectly on any crowded bench top. Fitted with a microprocessor controlled system, it features electronic calibration function and multiple block options.

  • Temperature range RT. 5°C ~ 100°C
    Temperature control range
    Temperature setting range
    Temperature accuracy ≤ ± 0.3°C
    Temperature uniformity ≤ ± 0.3 °C
    Temperature stability ± 0.3°C
    Block quantity
    Heating time ≤ 10 min (25°C ~ 100°C)
    Cooling time
    Display accuracy 0.1 °C
    Time range 1 min - 99 hr.
    Auto warming
    Auto running
    Auto heating
    Auto resume to run
    Multi points running
    Multi points running circularly
    Voltage AC 24 V/ 1.67 A
    Power 40 W
    Fuse
    Dimension (L x W x H) 260 x 195 x 150 mm
    Net weight 4.5 kg
    Gross Weight 4.5 kg
    • Microprocessor controlled device
    • Energy efficient structure
    • Electronic calibration function which can be reset to any standard by the users
    • UL, CSA and CE approved power supply
    • Befitting for 24 V power adapter
    • Experiment process is visible
    • Custom blocks available
    • Requires less bench space
    • Provides accuracy up to ± 0.3°C
    • 12-months warranty
  • Dry bath incubator can be used for: DNA amplification, enzyme-substrate reactions, serum coagulation, blood-urea nitrogen determination etc.

  • Model Diameter of test tube Capacity
    DBA-18 2.0 ml 15
    DBA-19 1.5 ml 15
    DBA-20 0.5 ml 24
    DBA-21 0.2 ml 32
    DBA-22 0.2 ml 32

Dry bath incubator LDBI-A10

  • RT. 5°C ~ 160°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 1 or 2Block quantity

Dry bath incubator LDBI-A11

  • RT. 5°C ~ 130°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 4Block quantity

Dry bath incubator LDBI-A21

  • RT. 5°C ~ 100°CTemperature range
  • 0 °C - 100 °CTemperature setting range
  • ≤ ± 0.3 °CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
Dry bath incubator LDBI-A30
  • RT. (-30) °C - 100°CTemperature control range
  • (-10) ℃ - 100 ℃Temperature setting range
  • ≤ ± 0.3 °CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity

Lighting Incubator LLI-A12

  • 450 LCapacity
  • 2 side illuminationIllumination type
  • Fluorescent lampLight source
  • 0 to 20000 lxLighting illumination

Lighting Incubator LLI-A11

  • 350 LCapacity
  • 2 side illuminationIllumination type
  • Fluorescent lampLight source
  • 0 to 15000 lxLighting illumination
Lighting Incubator LLI-A10
  • 250 LCapacity
  • 2 side illuminationIllumination type
  • Fluorescent lampLight source
  • 0 to 12000 lxLighting illumination
Roller Bottle Incubator LRBI-A10
  • 5 to 60°CTemperature range
  • ±0.5°C (ambient temperature 25°C, set value 37°C, 5 % no load)Temperature uniformity
  • ±0.2°C (ambient temperature 25°C, set value 37°C, 5 % no load)Temperature fluctuation
  • 0 to 20 %CO2 Concentration range

Dry bath incubator LDBI-A20

  • RT. 5°C ~ 100°CTemperature range
  • ≤ ± 0.3°CTemperature accuracy
  • ≤ ± 0.3 °CTemperature uniformity
  • ± 0.3°CTemperature stability

Dry bath incubator LDBI-A11

  • RT. 5°C ~ 130°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 4Block quantity
Dry bath incubator LDBI-A10
  • RT. 5°C ~ 160°CTemperature range
  • ± 0.5 °C at 40 °C ; ± 1 °C at 120°CTemperature accuracy
  • ± 0.5 °CTemperature uniformity
  • 1 or 2Block quantity
Biochemical Incubator LBCI-A11
  • 150 LCapacity
  • 0 to 60°CTemperature range
  • ± 0.5°CAccuracy
  • 0 to 60°CAmbient temperature

Biochemical Incubator LBCI-A12

  • 250 LCapacity
  • 0 to 60°CTemperature range
  • ± 0.5°CAccuracy
  • 0 to 60°CAmbient temperature

Biochemical Incubator LBCI-A10

  • 100 LCapacity
  • 0 to 60°CTemperature range
  • ± 0.5°CAccuracy
  • 0 to 60°CAmbient temperature
Gel Card Incubator LIGC-A10
  • 24 cardsCapacity
  • RT+5°C to 60°CTemperature range
  • ± 0.5°CTemperature accuracy
  • 0.1°CTemperature precision