Semi-automatic Biochemistry Analyzer LSBA-A10

Semi-automatic Biochemistry Analyzer LSBA-A10 also known as chemistry analyzer is tabletop unit comes with aspiration volume ranges from 100 to 5000 µl, offers absorbance ranges from 0 to 3.0 abs. Adopts turbidimetery and colorimetry principle, equipped with different wavelengths such as 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position. It provides easy, quick and accurate diagnosis of blood samples.

  • Absorbance Range 0 to 3.0 Abs
    Aspiration Volume 100 to 5000 µl
    Wavelengths 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position
    Principle Colorimetery, turbimetry
    Light Source Halogen lamp, 6 V 10 W
    Storage 15000 Results
    Test Method End Point, fixed time, kinetic
    Absorbance (340 nm) Variation ≤ 0.005 Abs
    Power Supply AC 100 to 240 V 50/60 Hz
    Dimension 355×330×175 mm
    Net Weight 5.6 kg
    • 5 inch touch screen and keypad for ease of monitoring
    • Equipped with reaction curve real time display
    • Integrated with test methods like kinetic, end point and fixed time
    • Provide storage of upto 15000 results
    • Built in with cuvettes modes and permanent quartz flowcell
    • Easy and less maintenance, easy-to-use operation software and LIS support
    • Halogen lamp with 2000 hours long life
  • Semi-automatic Biochemistry Analyzer is widely used in life sciences including biotechnology, microbiology, immunology, cell and molecular biology. It is commonly used in factories, clinics and laboratories.

Semi-automatic Bio-chemistry Analyzer LSBA-A21

  • Measuring Range: 0 to 3.0 OD
    Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear
    Photometric linearity: ±2% (0 to 3.000 OD)
    Photometric accuracy: ±1% (0 to 3.000 OD)
    Carry over: ≤1%
    Measuring System
  • Light source: 6 V, 10 W halogen lamp; standby function
    Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)
    Wavelength Accuracy: ±2 nm
    Photometric System
  • Temperature: 25˚C, 30˚C, 37˚C
    Precision: ±0.1˚C
    Thermostatic Control
  • <0.005 OD/hrDrift

Semi-automatic Bio-chemistry Analyzer LSBA-A20

  • Measuring Range: 0 to 3.0 OD
    Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear
    Photometric linearity: ±2% (0 to 3.000 OD)
    Photometric accuracy: ±1% (0 to 3.000 OD)
    Carry over: ≤1%
    Measuring System
  • Light source: 6 V, 10 W halogen lamp; standby function
    Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request)
    Wavelength Accuracy: ±2 nm
    Photometric System
  • Temperature: 25˚C, 30˚C, 37˚C
    Precision: ±0.1˚C
    Thermostatic Control
  • <0.005 OD/hrDrift

Semi-automatic Biochemistry Analyzer LSBA-A11

  • -0.3 to 3.0 absAbsorbency Range
  • 0.001 abs (display), 0.0001 abs (inner calculation)Resolution
  • ± 0.1°CTemperature Accuracy
  • 340 nm, 405 nm, 510 nm, 546 nm, 578 nm, 620 nm + 2 free positionsWavelength