Laser Particle Size Analyzer LLPA-A11

Laser Particle Size Analyzer LLPA-A11 is a fully automatic wet laser particle size analyzer, adopted with MIE scattering principle, dual-beam and multiple spectral detection systems, side light scatter test technology, and unconstrained free fitting software technology. Designed as per ISO13320-1:1999 standard configurations, offers 0.01 to 2000 μm of measuring range with 127 channels and 350 ml sample pool. Equipped with high-performance semiconductor laser and built-in dispersion unit, features auto optical alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion etc. Incorporated with intelligent SOP operation, automatic and manual mode, has different analysis mode, statistic methods, and statistic comparisons, offers <2 min test time and supports test report in various format.

  • Dispersion Type Wet
    Measurement Range 0.01 to 2000 µm
    Channel number 127
    Accuracy Error <1% (National Standard Sample D50)
    Repeatability Error <1% (National Standard Sample D50)
    Light Source High performance semiconductor laser λ = 632.8 nm,<br/> P > 2 mW,<br/> Service life > 25000 hours
    Detector Dual-beam and multiple spectral detection
    Dispersion Method
    • Ultrasonic Frequency: 40 kHz
    • Ultrasonic Power: 35 W
    • Ultrasonic Time: ≥ 1 s
    • Stir Revolution Speed: 0 to 3000 rpm (adjustable)
    • Circulation: Rated Flow: 8 L/min<br/> Rated Power: 10 W
    Sample Pool Capacity 350 ml
    Optical Path Alignment Fully automatic
    Operation mode Automatic/ Manual (Switchable)
    Standard ISO 13320-1:2010
    Test Speed <2 min/time
    Software Running WIN 7/10/XP, 64 bits
    Analysis mode Free Distribution, R-R Distribution, Logarithm Normal Distribution, Mesh number classification etc.
    Statistic Method Volume Distribution, Quantity Distribution
    Test Report Word, Excel, Photo( Bmp), Text etc.
    Intelligent operation Intelligent SOP operation
    Dimension (L×W×H) 660×320×400 mm
    Net Weight 65 kg
    • An intelligent and fully automatic wet laser particle size analyzers
    • Adopted with MIE scattering principle, highly sensitive detectors and detection system
    • Unconstrained free fitting software technology, facilitate the data processing
    • Designed as per ISO13320-1:1999 standard configurations
    • 0.1 to 300 µm measuring range with 39 channels and 350 ml sample pool
    • High-performance semiconductor laser and built-in dispersion unit
    • Auto optical alignment, auto water supply, auto drainage, auto bubble removing, auto ultrasonic dispersion etc.
    • Intelligent SOP operation with both automatic and manual operation mode
    • Different analysis mode, statistic methods, and statistic comparisons
    • <2 min test time with test report in various format for easy data analysis
    • High-efficient, stable and reliable unit to precisely determine the particle size distribution
  • Laser particle size analyzer is used to measure the sizes of particles in a material across cosmetics, food, coal, paint, paper, petrochemical, dyes, inks, explosives, , kaolin, medicine, metal powder, mica, milling, minerals, oxides industries etc.

  • 10 ml micro sample pool

Laser Particle Size Analyzer LLPA-A13

  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 87Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-C10

  • Wet and DryDispersion Type
  • Wet: 0.01 to 2000 µm
    Dry: 0.1 to 2000 µm
    Measurement Range
  • Silicon photodetectorsPhotodetectors
  • Wet: 127
    Dry: 100
    Channel number

Laser Particle Size Analyzer LLPA-A10

  • WetDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 39Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A12
  • WetDispersion Type
  • 0.1 to 1000 µmMeasurement Range
  • 90Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-B10
  • DryDispersion Type
  • 0.1 to 2000 µmMeasurement Range
  • 100Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Laser Particle Size Analyzer LLPA-B11

  • DryDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 40Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Spray particle size analyzer LSPA-A10

  • 1 μm - 2000 μmMeasuring range
  • Fraunhofer light diffractionPrinciple
  • 1 - 10 mSpray area range
  • Split-typeStructure

Laser Particle Size Analyzer LLPA-A10

  • WetDispersion Type
  • 0.1 to 300 µmMeasurement Range
  • 39Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A12
  • WetDispersion Type
  • 0.1 to 1000 µmMeasurement Range
  • 90Channel number
  • <1% (National Standard Sample D50)Accuracy Error
Laser Particle Size Analyzer LLPA-A11
  • WetDispersion Type
  • 0.01 to 2000 µmMeasurement Range
  • 127Channel number
  • <1% (National Standard Sample D50)Accuracy Error

Image particle shape and size analyzer LISA-A11

  • 2 μm to 6000 μmMeasuring range
  • Ultrasonic, Stirring, CirculationDispersion
  • High speed and resolution CCD (The shutter speed is 10-6/s)CCD
  • 1028 × 1024Maximum resolution

Image particle shape and size analyzer LISA-A10

  • 1μm to 6000 μmMeasuring range
  • Computer image analysis technologyTechnology
  • Morphology & sizeParticle properties measured
  • Aspect ratio, sphericity, surface ratio, specific surface area, circumscribed rectangle parameters etc.Particle shape parameters
Nano-particle size analyzer LNPA-A10
  • 1 nm-10000 nmMeasuring range
  • Dynamic light scattering & Brownian motionPrinciple
  • < 5 minTest speed
  • Suspension, emulsion and powdersSample type