Liquid Particle Counter LLPC-A20

Liquid Particle Counter LLPC-A20 is a benchtop equipment with the ability to handle viscosity of the sample up to 650 cSt. Features high precision sensors and syringe sampling system to obtain accurate results with good repeatability. There are 16 selectable channels with a measuring range of 0.8 to 600 µm. The results are displayed using four calibration curves which can also be stored and even switched to minimise conversion error. It has wide applications in petroleum industry, chemical industry, aerospace, machinery and many other fields.

  • Light source Semiconductor laser
    Measuring range 0.8 µm to 600 µm (Depends on the sensor)
    Sensitivity 0.8 µm (1S04402) or 3 µm (c)
    Measuring channels 16 channels, particle size can be set arbitrarily
    Sampling volume 0.2 to 100 ml, interval 0.1 ml
    Sampling volume precision Be superior to ± 0.5 %
    Sampling speed 5 to 80 ml/min
    Cleaning speed 5 to 80 ml/min
    Resolution Be superior to 10 % 1S011171
    Coincidence error limit 12000 to 40000 particles/ml (Depends on the sensor)
    Repeatability RSD < 2 %
    Count accuracy ± 10 %
    Air pressure chamber maximum vacuum - 0.08 mPa
    Air pressure chamber maximum pressure 1 mPa
    Test sample viscosity ≤ 650 cSt
    Test sample temperature 0°C to 80°C
    Work temperature 0°C to 60°C
    Storage temperature -30°C to 80°C
    Power supply 100 to 245 V, 49 to 62 Hz
    Overall dimensions Mainframe 430 × 320 × 590 mm<br/> Air pressure bump 330 × 266 × 255mm
    Instrument net weight Mainframe 30 kg <br/> Air pressure bump 10 kg
    • Based on Light Blocking Method to achieve rapid detection speed, accuracy and good repeatability
    • High precision sensors are used to get a higher resolution
    • Syringe sampling system: To achieve constant sampling speed and to control sample volume
    • Pressurized sample delivery to degas the sample and increase the accuracy
    • Color LCD display, touch screen, graphics menu to make the operations simple
    • Several standards to rate the particle pollution are stored and also new standards can also be added
    • Granularity and size of 9900 particles can be easily analysed through different channels
    • Four calibration curves: latex ball calibration curve, ACFTD calibration curve, ISDMTD calibration curve, GOST calibration curve
    • Curves can be switched to minimise conversion error and can be stored
    • Data storage function to retrieve the data easily
    • Test reports can be printed through built-in printer
    • Advanced software and RS232 interface to connect external computer
    • Magnetic stirring to distribute the particles evenly
      Gas filtration and purification system to eliminate contaminants from air pressure pump
  • It finds application in detection of solid pollutants in lubricating oil, insulating oil, hydraulic oil, aviation kerosene etc. It can trace the insoluble particles in polymer solution and organic liquid. Therefore it has wide applications in petroleum industry, chemical industry, automobile manufacturing, aerospace and many other fields.

Liquid Particle Counter LLPC-A10

  • 1 to 250 µm (25 sensors)
    1 µm to 320 µm (32 sensors)
    2 µm to 400 µm (40 sensors)
    Measurement range
  • Semiconductor laser lightLight Source
  • 8 channelsMeasurement Channels
  • 1 µm (2 µm) to arbitrarily set within 100 µmParticle size

Liquid Particle Counter LLPC-A20

  • Semiconductor laserLight source
  • 0.8 µm to 600 µm (Depends on the sensor)Measuring range
  • 0.8 µm (1S04402) or 3 µm (c)Sensitivity
  • 16 channels, particle size can be set arbitrarilyMeasuring channels

Liquid Particle Counter LLPC-A10

  • 1 to 250 µm (25 sensors)
    1 µm to 320 µm (32 sensors)
    2 µm to 400 µm (40 sensors)
    Measurement range
  • Semiconductor laser lightLight Source
  • 8 channelsMeasurement Channels
  • 1 µm (2 µm) to arbitrarily set within 100 µmParticle size