Semi-automatic Microtome LSAM-A10

Semi-automatic Microtome LSAM-A10 is a semi-automated unit with manual functionality for user convenience. Designed with built-in actuation system for precise tissue slicing, LCD display to show the slice and trimming thickness. Features a special sample retraction function preventing damage due to the abrasion between sample and the back of knife for smoother slicing, easy to dismantle waste bath dismantled, built-in safety alarm system alert the user for fault diagnosis.

  • Slice thickness range 0.5 µm to 100 µm (3 µm to 5 µm best slicing effect)
    Trimming section range 1 µm to 600 µm
    Horizontal specimen stroke 20 mm
    Vertical specimen stroke 55 mm
    Maximal slice section 50×45 mm
    Specimen retraction 20 µm
    Slip precision ± 5 %
    Section thickness setting 0.5 to 5 µm, in 0.5 µm increment<br/> 5 to 20 µm, in 1 µm increment<br/> 20 to 60 µm, in 5 µm increment <br/> 60 to 100 µm, in 10 µm increment
    Trimming thickness setting 1 to 10 µm, in 1 µm increment<br/> 10 to 20 µm, in 2 µm increment<br/> 20 to 50 µm, in 5 µm increment<br/> 50 to 100 µm, in 10 µm increment<br/> 100 to 600 µm, in 50 µm increment
    Packing Dimension 680×560×480 mm
    Gross Weight 50 kg
    • LCD screen shows the slice and trimming thickness
    • Adopted with advanced imported actuation system, for more precise tissue slicing
    • Sample retraction for prevention of sample damage
    • Can lock hand wheel in any position
    • Easy to disassembled waste bath
    • Safety alarm to alert the user for fault diagnosis
  • Semi-automatic Microtome widely used for sectioning (slicing, trimming) of biological specimens across Histopathology, Medicine filed for research and analysis.

  • Disposable Blade Holder 1 pc
    Specimen Cassette 1 pc
    Fuse (2A) 2 pcs
    Power line 1 line
    Hexagonal Wrench 1 set
    Brush 1 pc
  • Feather Microtome Blade

Automatic Microtome LAM-A10

  • 0.5 μm to 100 μm (3 to 5 μm best slicing effect)Section thickness range
  • 0.5 to 5 μm, in 0.5 μm increment
    5 to 20 μm, in 1 μm increment
    20 to 60 μm, in 5 μm increment
    60 to 100 μm, in 10 μm increment
    Section thickness setting
  • 1 to 600 μmTrimming thickness range
  • 1 to 10 μm, in 1 μm increment
    10 to 20 μm, in 2 μm increment
    20 to 50 μm, in 5 μm increment
    50 to 100 μm, in 10 μm increment
    100 to 600 μm, in 50 μm increment
    Trimming thickness setting

Rotary Microtome LRMI-A10

  • 0 to 60 µmSlice thickness range
  • 0 to 2 µm in 0.5 µm increment
    2 to 10 µm in 1 µm increment
    10 to 20 µm in 2 µm increment
    20 to 60 µm in 5 µm increment
    Section thickness setting
  • Horizontal: 20 mm; Vertical: 50 mmSpecimen stroke
  • ± 5%Slip precision
Semi-automatic Microtome LSAM-A10
  • 0.5 µm to 100 µm (3 µm to 5 µm best slicing effect)Slice thickness range
  • 1 µm to 600 µmTrimming section range
  • 20 mmHorizontal specimen stroke
  • 55 mmVertical specimen stroke
Vibrating Microtome LVMI-A10
  • 0 to 1.3 mm/s; AdjustableSpecimen sectioning speed
  • 0 to 1 mmVibrating range
  • 10 to 300 µmSection thickness range
  • 1 µmMinimum setting value