Semi-Automatic Kjeldahl Analyzer LKA-A20

LKA-A20 is a semi-automatic Kjeldahl analyzer having intelligent design. It is equipped with 4.3" LCD screen, automatic fault detection system and intelligent audible and visual alarm system. With features such as automatic alkali liquid quantification and filling, automatic boric solution quantification and filling, intelligent cooling water control system and emergency stop operation, it is a safe and reliable instrument.

  • Measuring Range 0.1 mg-250 mg N
    Analysis Time 3-4 min/sample
    Water Consumption in the Distillation Process 1.2-3 l/min
    Sample Capacity Solid : ≤ 6g/sample; Liquid: 16 ml/sample
    Burette volume
    Recovery ≥ 99.5 %
    Reproducibility
    Data Storage Capacity
    Power Supply AC 220 V ± 10%/ 50 Hz
    Power 2 kW
    Dimension 400 x 385 x 735 mm
    Net Weight 32.6 kg
    • 4.3" LCD display
    • Easy changeover of Manual/Automatic mode
    • Automatic quantification and filling of alkali liquid and boric solution
    • Automatic cleaning of control system and distiller
    • Automatic alarm function on completion of process
    • Perfect safety system ensures protection against over temperature and over pressure
    • Intelligent cooling water control system
    • Emergency stop operation to deal with unexpected accidents
    • Distillation time can be set freely
    • Automatic or manual filling mode is optional according to the test need
    • Automatic fault detection system
    • Intelligent audible and visual alarm system available
  • It is used to perform nitrogen analysis and protein determination in food & feed industry, environmental industry, chemical industry etc.

  • Accessory Name Quantity
    Digestion Tubes 10 pcs
    Power Cord 1 pc
    Alkali/ Water/ Acid Tanks 3 pcs
    Inlet Water Pipe 1 pc
    Draining Pipe 1 pc
    Waste Receiving Tray 1 pc
    Nylon Cable Ties 10 pcs
  • Accessory Name Specification Quantity
    Digestion Tube 280 ml 10
    Alkali Tank 300 ml 3
    Boric Acid Tank
    Water Tank

Related Products of Kjeldahl Analyzer

Labtron produces high performance TKA series of Kjeldahl Analyzer which is designed on classic Kjeldahl nitrogen determination method. Its latest core control system and fully automatic features attracts users worldwide.

Fully-automatic Kjeldahl Analyzer LKA-C10

  • 0.1 to 200 mgNMeasurement Range
  • Automatic test module of conventional NitrogenFunction
  • ≥ 99.5 %Recovery Rate
  • Solid ≤ 5 g   liquid ≤ 25 mlSample

Kjeldahl Analyzer LKA-A10

  • 0.1 mg-200 mg NMeasuring Range
  • 5-10 min/sampleAnalysis Time
  • 1.5 l/minWater Consumption in the Distillation Process
  • Solid : ≤ 5g/sample; Liquid: 20 ml/sampleSample Capacity

Graphite Digester

Graphite digesters are used to simplify operations and meet the highest safety requirements. It ensure reproducible digestion due to the improved thermal homogeneity and accurate temperature control

Graphite Block Kjeldahl Digester LKGD-A11

  • 5 °C - 450 °CTemperature Range
  • 280 mlDigestion Tube Capacity
  • 20 pcs / batchCapacity Per Batch
  • Infrared heating and high-purity graphite conductionHeating Method

Graphite Kjeldahl Digester LKGD-A10

  • 5 °C - 450 °CTemperature Range
  • 280 mlDigestion Tube Capacity
  • 20 pcs / batchCapacity Per Batch
  • Infrared heating and high-purity graphite conductionHeating Method

Kjeldahl Analyzer

Labtron produces high performance TKA series of Kjeldahl Analyzer which is designed on classic Kjeldahl nitrogen determination method. Its latest core control system and fully automatic features attracts users worldwide.

Semi-Automatic Kjeldahl Analyzer LKA-A20
  • 0.1 mg-250 mg NMeasuring Range
  • 3-4 min/sampleAnalysis Time
  • 1.2-3 l/minWater Consumption in the Distillation Process
  • Solid : ≤ 6g/sample; Liquid: 16 ml/sampleSample Capacity
Fully-automatic Kjeldahl Analyzer LKA-C10
  • 0.1 to 200 mgNMeasurement Range
  • Automatic test module of conventional NitrogenFunction
  • ≥ 99.5 %Recovery Rate
  • Solid ≤ 5 g   liquid ≤ 25 mlSample

Kjeldahl Analyzer LKA-A10

  • 0.1 mg-200 mg NMeasuring Range
  • 5-10 min/sampleAnalysis Time
  • 1.5 l/minWater Consumption in the Distillation Process
  • Solid : ≤ 5g/sample; Liquid: 20 ml/sampleSample Capacity