A PHP Error was encountered

Severity: Warning

Message: fopen(/var/cpanel/php/sessions/ea-php80/ci_session96986cf39be6ef005f3bc58f76a2d6d0e8784250): Failed to open stream: No such file or directory

Filename: drivers/Session_files_driver.php

Line Number: 176

Backtrace:

File: /home/zytronis/labtron.best/application/controllers/Website.php
Line: 8
Function: __construct

File: /home/zytronis/labtron.best/index.php
Line: 318
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/cpanel/php/sessions/ea-php80)

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home/zytronis/labtron.best/application/controllers/Website.php
Line: 8
Function: __construct

File: /home/zytronis/labtron.best/index.php
Line: 318
Function: require_once

Differential Scanning Calorimeter LDSC-A11

Differential Scanning Calorimeter LDSC-A11

Differential Scanning Calorimeter LDSC-A11 is an analyzer which allows the measurement of different characteristic properties of various samples from RT to 600°C. It meets ASTM, ISO standards. High resolution, stable base line, air flow meter, bilateral control etc. are some of the features which ensures accurate and reliable results. It finds applications in fields like polymer development, quality control of different materials, performance testing and many other industries.

  • Temperature range RT to 600°C (Air cooled)
    Temperature resolution 0.1°C
    Temperature fluctuations ± 0.1°C
    Temperature repeatability ± 0.1°C
    Dynamic heat flow range (DSC range) 0 to ± 500 mW
    Heating rate 1 to 80°C / min
    Cooling rate 1 to 20°C / min
    DSC noise 0.01 μW
    DSC resolution 0.01 µW
    DSC accuracy 0.1 µW
    DSC sensitivity 0.1 µW
    Control Mode Rising temperature, constant temperature (full automatic)
    Curve scanning Rising scan, cooling scan
    Gas flow control Embedded digital flow meter & Software control, automatic changing
    Parameter standard With standard material, with calibration function, the user may correct temperature and heat enthalpy
    Display 24 bit 7 inches LCD touch screen display
    Data interface Standard USB connector
    Power Consumption Less than 2000 W
    Packaging Dimension and Gross weight (2 case) 580×490×520 mm / 29 kg<br/> 530×270×280 mm / 15 kg
    • Renewed design of oven structure
    • High stability and resolution of base line
    • Accurate control of air flow rate
    • Test data storage function
    • Both main frame and software control option
    • LCD touch screen display
    • Meets ISO and ASTM standards
  • It is used to study thermal transitions, heat capacity, glass transition temperature, crystallinity, melting temperature etc. of various materials like polymers, plastics, elastomer, food stuffs, biomolecules, non-corrosive samples, electronic components etc.

  • Name of Accessories Quantity
    Host instrument 1
    CD 1
    Data Line 1
    Power Line 1
    Aluminium crucibles 100
    Ceramic crucibles 100
    pure tin grains 1bag
    Fuse 4A 5

Differential Scanning Calorimeter LDSC-A10

  • RT to 800°C (Air cooled)Temperature range
  • 0.1°CTemperature resolution
  • ± 0.1°CTemperature fluctuations
  • ± 0.1°CTemperature repeatability

Differential Scanning Calorimeter LDSC-A12

  • -100°C to 800°C (Liquid nitrogen refrigeration)Temperature range
  • 0.1°CTemperature resolution
  • ± 0.1°CTemperature fluctuations
  • ± 0.1°CTemperature repeatability